Gas analyser and opacimeter RY-500AGH

The gas analyser  is a device for the detection of ignition and injection problems, as well as for the improvement of fuel consumption. Based on infrared technology measures up to 5 gases; CO, CO2, HC, O2, NOx (optional), and other parameters such as Lambda, corrected CO, oil temperature and rpm.

The opacimeter is a partial flux meter based on the principle of light absorption by smoke. It allows an official opacity test to be carried out, guided step-by-step by the programme.

In short, our RY-500-AGH unites the technology of our RY-500AG and RY-500AH in a single solution.

Standard equipment

  • Gas analyser module
  • Smoke analyser module
  • Sampling probe
  • Special cabinet for emissions equipment
  • Electronic control and SMRW Software
  • Temperature and RPM measuring sensors
  • Commissioning certificate for opacimeter module F

Technical data

Gas analyser

  • Measurable gases

    HC, CO, CO₂, O₂, NOx (optional)

  • Calculation of Lambda factor and corrected CO
  • Storage temperature

    -50 to 70 ºC

  • Operating temperature-10 to 55 ºC
  • Atmospheric pressure750-1,150 mbar
  • Power supply115-230 V 1.5 A / 47 - 63 Hz
  • Oil Temperature/Resolution Meter-5 to 150 ºC / 1 ºC
  • RPM/resolution meter0-9.999 rpm / 10 rpm
  • Lambda meter/resolution0-9,99 / 0,001 o 0,01
  • Regulations it complies withOIML R99 / ISO 3930 / BAR97
  • Database and scrap assessment available
  • Dimensions

    400 x 400 x 190 mm

Opacimeter

  • Environmental working conditions: TemperatureAmb. temp. in use: -10 to 55ºC / Amb. temp. in official use: 0 to 45ºC
  • Environmental working conditions: Humidity30-90%
  • Environmental working conditions: Pollution<2%
  • Storage temperature-32 to 55ºC
  • OpticsGreen light source between 480 and 680 mm, max. 565 mm
  • DetectorSilicon photodiode
  • Response timeFrom 10 to 90%, <0,2 s
  • Acoustic noise53 dB
  • Warm-up period3-6 min, depending on outside temperature
  • Standard test probe745 mm / 10 mm
  • Opacity (range, resolution)N: 0-100% / 0,10% K: 0,00-9,99 m-1 / 0,01 m-1
  • Power supply230 V 50 Hz
  • Regulations it complies with

    ISO 11614, EMC Standard UNE 82503, NFR 10025-2016

  • Measurement of the opacity at % and the absorption coefficient "k", calculated according to Beer-Lambert's Law
  • Dimensions

    500 x 250 x 450 mm.

Gas Analyser and Opacimeter Software

Ryme Worldwide has SMRW (Software Maquinaria Ryme Worldwide) for its equipment, which is responsible for collecting information from our equipment and peripherals, analysing it and displaying it on the information output device. All of this is accompanied by the necessary electronics to optimise performance to the maximum.

Work in your inspection centre or workshop in the fastest and most efficient way with the operation of our Ryme Worldwide Machinery Software.

A unique way of working designed to make the inspector's job easier.

No redundancies, what you need, when you need it, how you need it. Read more 

Get to know all our software and management systems

e-swift
VISION